故障现象 笔者某次配置了一个16日的AM模块。出现了一个奇怪的问题。配置好后,拨入时没有Modem拨号声。只有电话的声。并且音指示灯也不亮。当笔者拔下模块上的电话线时。指示灯亮了。
620#sh run Building configuration...
Current configuration : 866 bytes ! version 12.2 service timestamps debug uptime service timestamps Jog uptime no service password-encryption ! hostname2620 enable secret 5 $1$pUrf$9xGOg.zyxKawi9NljLHHr1 usernameuser password 0 Cisco ip subnet-zero ! ! no ip domain-lookup ! ! ! ! interface FastEthernet0/0 ip address 136.0.0.254255.255.0.0 duplex auto speed auto ! interface Group-Async1 ip unnumbered FastEthernet0/0 encapsulation ppp async default routing async mode interactive peer default ip address pool lab ppp authentication chap group-range 33 48 ! ! ip classless no ip http server ip pim bidir-enable ! ! line con 0 password cisco line 33 48 login local modem InOut autocommand ppp transport input all autoselect ppp stopbits 1 flowcontrol hardware line aux0 line vty 0 4 password Cisco login ! no scheduler allocate end 诊断过程 笔者仔细检查配置文件,发现缺少ip pool,加上ip local pool lab(start ip addr)(stop ip addr),没有效果。后来笔者想到拨号采用的都是模拟信号,与接地有很大关系。没自动应答:多半是接地问题。所以直接把路由器上的接地螺钉,用一根导线接到防静电地板下面的铁支柱上,问题解决了。 排除心得 路由器标准接地的方法是在铺设电源线的时候放置一根地线,然后路由器的外壳接到地线上去就好,笔者估计原来负责网络系统搭建的厂商采用的电源线忽略了地线,否则也不会出现这样的问舰。接路由器电源的时候如果有地线,一般不需要我们再接地了。
|
·Juniper M系列路由器扩展安全路由架构应用 (9-22) ·现在是DIY时代 自制宽带路由器上网 (9-17) ·路由器命令一览 网管常用的网络命令集 (9-16) ·路由器端口映射的原理及设置方法介绍 (8-26) ·为你规划网络 成长型企业路由器选购分析 (8-21) 热议文章·高端的口号低端的招标 电信招标有类联通 (9-18) 评:其实我觉得电信可以采用机卡一体机和机卡分离机并举的形式解决终端问题,毕竟世界范围... ·重组后的中国联通,何以对抗即将到来的混战 (9-17) ·评论:如何击中中移动的软肋 (9-11) ·联通华盛易主中国电信 新联通组建终端公司华凯 (9-7) ·国资委专家细述电信失衡两诱因 (8-27) ·联通网通合并后名称暂定为联合网络通信公司 (8-27) ·现在部署WiMAX还是等待LTE? (8-27) ·思博伦CDMA2000协议测试系统 (9-25) ·华为改造苏州CDMA网络方案 (9-25) ·网络布线中的光纤连接技术深入分析 (9-25) ·全业务转型过程中的OSS建设方向 (9-25) ·有关PB/Sybase开发过程中数据库转移介绍 (9-25) ·SQL Server 2008数据库中如何使用表值参数 (9-25) |
|||||||||||||||
|